ATAG error codes — full list with meanings | TroubleAtlas

🌐 ▾
HVAC Error Codes · Manufacturer index

ATAG error codes

The complete list of ATAG fault codes shown on the display, each with what it means and the page that explains how it is diagnosed and fixed.

32documented codes
32with documented causes
6.5TroubleAtlas Score
ATAG boiler with the fault code shown on the display
Quick Answer

ATAG heating appliances display 32 documented error codes. Each code below opens its own page with the official meaning, the documented causes, the safety assessment and the parts involved.

01

All ATAG Error Codes

32 codes, each with its own page. Click a code to open the meaning, the documented causes and the repair.

CodeWhat it meansSeverity
102Pressure sensor fault—
110Safety temperature exceeded / Send sensor damaged—
112Return sensor error – could be damaged—
114Outdoor sensor error – could be damaged—
117Pressure too high ( 3 bar, 43.5 psi) or pump pressure increase too high (iC & iS Range only)—
118Pressure too low ( 1 bar, 14.5 psi) or pump pressure increase too low) no pump detection) (iC & iS Range only)—
129Fan error (fan does not start up)—
133No flame after 5 ignition attemptsHIGH
141Central heating flow switch is open—
151Fan error (speed control is not achieved or is out of range) or control unit defective—
20Flow sensor error—
201Domestic hot water (DHW) sensor damaged—
203Tank sensor damaged—
303Printed circuit board ( PCB ) error—
40Return sensor error—
50DHW sensor error (iC-Range only)—
61Bus communication error—
612Fan fault – fan isn’t starting up—
78Water pressure out of range—
A4Flue gas temperature (only if a flue gas sensor is connected)HIGH
P1050 Common flow sensor T10 0-1 0: autodetect 1: connected—
P1220 DHW temperature sensor T3 0-1 0: autodetect 1: connected—
P1321 Pump continuously 1-2 1:Unit pump—
P160100% Maximum pump capacity (only with modulating circulation pump) 30-100—
P17190 Switch off moment relay external heating source 0-100% When demand is lower then adjusted value the…—
P1791 Overrun time cylinder pump—
P1815 Minimum cool down DHW temperature in °C (if—
P1821 Load adjustment due to temperature fall DHW in °C/10sec—
P18365 DHW Anti legionella temperature (if—
P19080 Flow temperature T10 at DHW in °C (using cylinder thermostat) (if—
P2032 Overrun time secondary pump—
P40% Correction factor fan speed—
02

What Fails Most Often on ATAG

Grouped from the official meaning of each of the 32 codes above — not from opinion. The number is how many different fault codes point at that component.

ComponentCodesExamples
Pump5117, P132, P160, P179
Temperature Sensor4102, 110, 114, 203
Fan4129, 151, 612, P4
Dhw Sensor3201, 50, P122
Return Sensor2112, 40
Water Pressure2118, 78
Flow Sensor220, P105
03

Parts & Prices

The parts most often involved in the ATAG faults listed above.

Circulating pump
OEM Part · ATAG
Check price View price
Temperature sensor (NTC)
OEM Part · ATAG
Check price View price
Fan / blower assembly
OEM Part · ATAG
Check price View price
Domestic hot water sensor
OEM Part · ATAG
Check price View price
Compatible Circulating pump
Compatible · Generic
Check price View price
Compatible Temperature sensor (NTC)
Compatible · Generic
Check price View price
Compatible Fan / blower assembly
Compatible · Generic
Check price View price
Compatible Domestic hot water sensor
Compatible · Generic
Check price View price
Reconditioned Circulating pump
Used / Tested · ATAG
Check price View price
Reconditioned Temperature sensor (NTC)
Used / Tested · ATAG
Check price View price
Reconditioned Fan / blower assembly
Used / Tested · ATAG
Check price View price
Reconditioned Domestic hot water sensor
Used / Tested · ATAG
Check price View price

Prices and availability vary by region and are shown by the retailer, not by TroubleAtlas.

04

Diagnostic Tools

What an engineer uses to work through the codes on this page.

Digital Multimeter (TRUE RMS)

For testing electrode resistance and PCB voltages

$35–$80 View price

Gas Leak Detector

Essential for checking connections after any gas valve work

$25–$45 View price

Manometer / Pressure Gauge

To measure gas inlet and burner pressure

$40–$90 View price

Combustion Analyzer

For verifying flue gas readings after repair

$180–$350 View price
Full HVAC diagnostic toolkit
05

TroubleAtlas Score — ATAG

TROUBLEATLAS · SCORE INDEPENDENT · VERIFIED ★★ TA 6.5/10

How ATAG scores

Efficiency4.7/10
Documentation8.0/10
Maintenance5.5/10
Safety7.6/10

Independently assessed across six dimensions from the documentation, the fault codes and the parts network. Based on 101 error codes across 12 appliances.

How we calculate it →
06

TroubleAtlas Pro

TroubleAtlas Pro — professional HVAC tools
For HVAC Professionals

Get cited by AI. Get found by customers.

TroubleAtlas Pro puts your business in front of homeowners searching for ATAG faults, and structures your listing so AI assistants can cite you as a trusted source.

Explore TroubleAtlas Pro →

Considering a New Heating System

Considering a New Heating System?

If your ATAG appliance is over 10 years old, replacing it with a modern condensing boiler or air-source heat pump could cut energy bills and remove the recurring faults listed on this page.

Compare Heating System Prices →
Professional heating system installation and service

YouTube Channel

TroubleAtlas · on YouTube

Watch the fixes. Follow the channel.

Step-by-step boiler repair guides, equipment reviews and heating system comparisons from qualified engineers.

New fixes every week
Weekly

Fix in 5

Quick fixes for common boiler faults explained in under 5 minutes

Head-to-Head

Boiler Comparator

Side-by-side comparisons of popular boiler models

Scored

Boiler Reviews

Independent reviews with TroubleAtlas Score ratings

Find a Specialist

Find help near you

Don’t fix it alone. Find a trusted heating engineer near you.

TroubleAtlas connects you with vetted local heating professionals who can inspect, diagnose and repair your ATAG appliance safely — no guesswork, no unnecessary call-outs.

VettedNear youDirect contact
Are you a professional? Join our network →
Suggested engineer · your city Certified heating technician

Local heating professionals are coming to your area

We’re onboarding Gas Safe registered and licensed HVAC engineers city by city. Check back soon, or search above to see current availability.

Written by TroubleAtlas Technical Team · Last updated: 2026-08-02 · Sources: manufacturer service documentation · How we verify