Elapsed time gas valve open without gas (short request in a short period)
The E134 error code on Baxi boilers indicates elapsed time gas valve open without gas (short request in a short period).
Baxi E134 means: elapsed time gas valve open without gas (short request in a short period). The usual causes are gas valve coil failure (electrical fault), gas valve stuck closed or partially open or gas supply interrupted (prepayment meter, emergency control valve). A Gas Safe registered engineer should diagnose the root cause.
What Does E134 Mean
The E134 code is shown by the boiler’s control board when it detects elapsed time gas valve open without gas (short request in a short period). The boiler then stops instead of continuing to run in that condition: the code is the appliance reporting a problem, not proof that the boiler is broken.
| What you see on the boiler |
|---|
| The display shows E134 and the boiler stops until the fault is cleared |
Common Causes
Causes documented in 1 technical sources.
| Cause |
|---|
| Gas valve coil failure (electrical fault) |
| gas valve stuck closed or partially open |
| gas supply interrupted (prepayment meter, emergency control valve) |
| incorrect gas pressure (too high or too low) |
| gas valve wiring fault |
| PCB not sending open signal to the gas valve |
Safety Warning
E134 is a gas-related fault. Never attempt to repair or adjust the gas valve, burner assembly, or flue system yourself. All gas work must be carried out by a Gas Safe registered engineer (UK) or licensed HVAC technician (US). Repeated resets after ignition failure can cause unburnt gas to accumulate inside the combustion chamber — this is a serious safety hazard. If you smell gas at any point, turn off the gas supply at the meter, open windows, leave the property, and call your gas emergency service immediately. Gas-related fault. Do not open the boiler casing or attempt repairs to the gas valve, burner, ignition or flue. Repeated resets are unsafe. Diagnosis and repair must be carried out by a Gas Safe registered engineer.
Parts & Prices
Prices shown are indicative. Actual prices and availability vary by region.
Step-by-Step Diagnosis
Check the gas supply — verify the gas meter is on and other gas appliances in the property work
Check the gas isolation valve at the boiler is fully open
Measure the inlet gas pressure at the boiler test point — should be 20 mbar (8.0 in wc) for natural gas (UK)
During ignition, measure the voltage at the gas valve coil terminals — the PCB should send a signal
If the valve receives voltage but does not open, the gas valve is faulty
Check the gas rate at the meter against the manufacturer's data
How to Fix It
Restore the gas supply if interrupted
replace the gas valve if it is stuck or electrically faulty — Gas Safe registered engineer only
adjust gas pressure if out of specification
repair wiring between gas valve and PCB
if PCB is not sending signal, replace the PCB. Warning: never attempt gas work unless you are Gas Safe registered
Refer to the Baxi service documentation for the detailed procedure. Only a qualified engineer should carry out these repairs.
Diagnostic Tools
TroubleAtlas Score
What Is the TroubleAtlas Score?
Every boiler model is independently evaluated and scored by TroubleAtlas across 6 dimensions: reliability, efficiency, parts availability, service network, value for money, and user satisfaction. The score helps you compare models and make informed decisions when choosing a new boiler.
See All Boiler Scores →Boiler Breakdown Cover
Boiler Breakdown Cover
Protect against unexpected repair costs. Cover plans include annual service, emergency callouts within 24 hours, and full parts replacement. Compare plans side by side and choose the level of protection that fits your home and budget.
Coverage Plans — Coming SoonConsidering a New Heating System
Considering a New Heating System?
If your boiler or heat pump is over 10 years old, replacing it with a modern condensing boiler or air-source heat pump could save you up to 30% on energy bills and significantly reduce your carbon footprint.
Compare Heating System Prices →
YouTube Channel
Watch the fixes. Follow the channel.
Step-by-step boiler repair guides, equipment reviews, and heating system comparisons from qualified engineers.
New fixes every weekFix in 5
Quick fixes for common boiler faults explained in under 5 minutes
Boiler Comparator
Side-by-side comparisons of popular boiler models
Boiler Reviews
Independent reviews with TroubleAtlas Score ratings
Find a Specialist
Don’t fix it alone. Find a trusted heating engineer near you.
TroubleAtlas connects you with vetted local heating professionals who can inspect, diagnose and repair your boiler safely — no guesswork, no unnecessary call-outs.
Local heating professionals are coming to your area
We’re onboarding Gas Safe registered and licensed HVAC engineers city by city. Check back soon, or search above to see current availability.
TroubleAtlas Pro
Get cited by AI. Get found by customers.
TroubleAtlas Pro puts your business in front of homeowners searching for exactly this fault, and structures your listing so AI assistants can cite you as a trusted source.
- ✓ Appear on error code pages viewed by thousands of homeowners
- ✓ AI assistants cite your listing as a verified local specialist
- ✓ Receive direct leads with customer name and contact details
- ✓ TroubleAtlas Certified badge for your marketing materials
Affected Models
Baxi models that can display fault code E134:
| Model Family | Output Range | Frequency |
|---|---|---|
| All Baxi models | — | Possible |
Frequently Asked Questions
Restore the gas supply if interrupted. According to the technical documentation, this is the first check on the list for E134.
E134 is classified as a high-severity fault: it involves gas, combustion or flue components. Do not keep resetting the boiler and do not attempt the repair yourself — call a Gas Safe registered engineer.