Viessmann error codes — full list with meanings | TroubleAtlas

🌐 ▾
HVAC Error Codes · Manufacturer index

Viessmann error codes

The complete list of Viessmann fault codes shown on the display, each with what it means and the page that explains how it is diagnosed and fixed.

62documented codes
8with documented causes
8.9TroubleAtlas Score
Viessmann boiler with the fault code shown on the display
Quick Answer

Viessmann heating appliances display 62 documented error codes. Each code below opens its own page with the official meaning, the documented causes, the safety assessment and the parts involved.

01

All Viessmann Error Codes

62 codes, each with its own page. Click a code to open the meaning, the documented causes and the repair.

CodeWhat it meansSeverity
02Burner control switches to lockout—
0ABurner control switches to lockout—
0DBurner control switches to lockout—
25Boiler operates with high boiler water temperature—
35Boiler does not activate—
A2KM-BUS fault to VitocomHIGH
A20A.20 Service interval could not be activated—
A3Abgastemperatursensor nicht richtig positioniertHIGH
DAKurzschluss Raumtemperatursensor Heizkreis 1 (ohne Mischer)—
F100F.100 Electronics modules connec- ted to PlusBus not function- ing Voltage error PlusBus Check whether the…—
F162F.162 Burner in a fault state Processor low voltage Turn the appliance off and on again—
F182F.182 No DHW heating Short circuit, outlet tem- perature sensor (if instal- led) Check the outlet temperature…—
F183F.183 No DHW heating Lead break, outlet temper- ature sensor (if installed) Check the outlet temperature sen-…—
F184F.184 Burner in a fault state Short circuit, flow temper- ature sensor/high limit safety cut-out Check the…—
F30F.30 Regulates without flow tem- perature sensor for low loss headerHIGH
F346F.346, F.377 Check gap between ionisa- tion electrode and burner gauze assemblyHIGH
F353F.353 Burner shutdown with restart if demand exists Insufficient gas supply, burner output reduced Check the…HIGH
F354F.354 Burner in a fault state Gas modulation valve tol- erance outside permissi- ble range Check connecting…—
F355F.355 Burner in a fault state Analogue signal reference check: Flame signal is al- ready present at burner…—
F369F.369, F.380 Check distance of ionisation electrode on burner gauze assembly—
F375F.375, F.377 Check gap between ionisa- tion electrode and burner gauze assemblyHIGH
F377F.377 Check gap between ionisa- tion electrode and burner gauze assemblyHIGH
F380F.380 Check distance of ionisation electrode on burner gauze assembly—
F381F.381 Burner in a fault state Flame loss during operat- ing phase Check gas supply (gas pressure and gas flow…HIGH
F416F.416 appears on the displayHIGH
F425F.425 System in control mode, cal- culation out of operation Time synchronisation failed Set the time—
F429F.429 Control mode Lead break, air mass sen- sor, fan unit Check connecting cable and plug- in connector—
F430F.430 Control mode operation in line with set values of heat generator Communication error, gateway Check…—
F432F.432 Burner blocked if fault occurs multiple times—
F433F.433 Burner blocked if fault occurs multiple times—
F446F.446 Burner in a fault state Deviation, heat generator flow temperature sensor/ high limit safety cut-out…—
F461F.461 Burner in a fault state Feedback signal of flue gas damper connection at EM-EA1 extension input (DIO…HIGH
F462F.462 Burner in a fault state LPG safety valve (sole- noid valve) at EM-EA1 ex- tension does not open (DIO…—
F463F.463 Burner in a fault state Contaminated combustion air, flue gas recirculation Heat generator installation…HIGH
F467F.467 Burner in a fault state Gas supply insufficient during calibration Test static gas pressure and gas…HIGH
F473F.473 No heat demand HMU heat management unit communication error Check connecting cable between burner…—
F530F.530 Solar function limited Sensor value not available or lead break of one or more sensors/missing…—
F538F.538 No solar central heating backup Lead break, system return temperature sensor Check the temperature…—
F539F.539 No solar central heating backup Short circuit, system re- turn temperature sensor Check the temperature…—
F543F.543 Mixer closes—
F545F.545 Mixer closes—
F547F.547 Mixer closes—
F549F.549 Mixer closes—
F574F.574 Control mode without room influence Room temperature sensor for heating circuit 1 not available Check…—
F575F.575 Control mode without room influence Lead break, room temper- ature sensor, heating cir- cuit 1 Check…—
F576F.576 Control mode without room influence Short circuit, room tem- perature sensor, heating circuit 1 Check…—
F577F.577 Control mode without room influence Room temperature sensor for heating circuit 2 not available Check…—
F578F.578 Control mode without room influence Lead break, room temper- ature sensor, heating cir- cuit 2 Check…—
F579F.579 Control mode without room influence Short circuit, room tem- perature sensor, heating circuit 2 Check…—
F58F.58 Control mode without room influence Short circuit, room tem- perature sensor Check plug and cable of…—
F580F.580 Control mode without room influence Room temperature sensor for heating circuit 3 not available Check…—
F581F.581 Control mode without room influence Lead break, room temper- ature sensor, heating cir- cuit 3 Check…—
F582F.582 Control mode without room influence Short circuit, room tem- perature sensor, heating circuit 3 Check…—
F6Temperaturwerte der Kesseltemperatursensoren weichen zu weit voneinander abHIGH
F65F.65 Burner starts again Flame signal is not present or insufficient at burner startHIGH
F67F.67 Burner in a fault state Ionisation current lies out- side the permissible range Check gas supply (gas…HIGH
F68F.68 Burner in a fault state Flame signal is already present at burner start—
F684F.684 Burner in a fault state Back draught safety de- vice faulty Check the back draught safety de- vice and…—
F89F.89 No central heating and no DHW heating Internal circulation pump blocked Check circulation pump—
F91F.91 Function of affected exten- sion in emergency mode DIO electronics module communication error Check…—
F92F.92 Function of affected exten- sion in emergency mode ADIO electronics module communication error Check…—
F93F.93 Function of affected exten- sion in emergency mode—
02

What Fails Most Often on Viessmann

Grouped from the official meaning of each of the 62 codes above — not from opinion. The number is how many different fault codes point at that component.

ComponentCodesExamples
Temperature Sensor13F182, F183, F184, F30
Flue6F346, F354, F375, F377
Control Board5F100, F462, F91, F92
Pump5F543, F545, F547, F549
Communication4A2, F416, F430, F473
Ignition4F355, F381, F65, F68
Fan3F429, F432, F433
Room Sensor3F574, F577, F580
03

Parts & Prices

The parts most often involved in the Viessmann faults listed above.

Temperature sensor (NTC)
OEM Part · Viessmann
Check price View price
Flue / air intake seal kit
OEM Part · Viessmann
Check price View price
PCB (printed circuit board)
OEM Part · Viessmann
Check price View price
Circulating pump
OEM Part · Viessmann
Check price View price
Compatible Temperature sensor (NTC)
Compatible · Generic
Check price View price
Compatible Flue / air intake seal kit
Compatible · Generic
Check price View price
Compatible PCB (printed circuit board)
Compatible · Generic
Check price View price
Compatible Circulating pump
Compatible · Generic
Check price View price
Reconditioned Temperature sensor (NTC)
Used / Tested · Viessmann
Check price View price
Reconditioned Flue / air intake seal kit
Used / Tested · Viessmann
Check price View price
Reconditioned PCB (printed circuit board)
Used / Tested · Viessmann
Check price View price
Reconditioned Circulating pump
Used / Tested · Viessmann
Check price View price

Prices and availability vary by region and are shown by the retailer, not by TroubleAtlas.

04

Diagnostic Tools

What an engineer uses to work through the codes on this page.

Digital Multimeter (TRUE RMS)

For testing electrode resistance and PCB voltages

$35–$80 View price

Gas Leak Detector

Essential for checking connections after any gas valve work

$25–$45 View price

Manometer / Pressure Gauge

To measure gas inlet and burner pressure

$40–$90 View price

Combustion Analyzer

For verifying flue gas readings after repair

$180–$350 View price
Full HVAC diagnostic toolkit
05

TroubleAtlas Score — Viessmann

TROUBLEATLAS · SCORE INDEPENDENT · VERIFIED ★★ TA 8.9/10

How Viessmann scores

Reliability6.0/10
Efficiency9.4/10
Documentation9.8/10
Maintenance9.4/10
Safety9.8/10

Independently assessed across six dimensions from the documentation, the fault codes and the parts network. Based on 249 error codes across 36 appliances.

How we calculate it →
06

TroubleAtlas Pro

TroubleAtlas Pro — professional HVAC tools
For HVAC Professionals

Get cited by AI. Get found by customers.

TroubleAtlas Pro puts your business in front of homeowners searching for Viessmann faults, and structures your listing so AI assistants can cite you as a trusted source.

Explore TroubleAtlas Pro →

Considering a New Heating System

Considering a New Heating System?

If your Viessmann appliance is over 10 years old, replacing it with a modern condensing boiler or air-source heat pump could cut energy bills and remove the recurring faults listed on this page.

Compare Heating System Prices →
Professional heating system installation and service

YouTube Channel

TroubleAtlas · on YouTube

Watch the fixes. Follow the channel.

Step-by-step boiler repair guides, equipment reviews and heating system comparisons from qualified engineers.

New fixes every week
Weekly

Fix in 5

Quick fixes for common boiler faults explained in under 5 minutes

Head-to-Head

Boiler Comparator

Side-by-side comparisons of popular boiler models

Scored

Boiler Reviews

Independent reviews with TroubleAtlas Score ratings

Find a Specialist

Find help near you

Don’t fix it alone. Find a trusted heating engineer near you.

TroubleAtlas connects you with vetted local heating professionals who can inspect, diagnose and repair your Viessmann appliance safely — no guesswork, no unnecessary call-outs.

VettedNear youDirect contact
Are you a professional? Join our network →
Suggested engineer · your city Certified heating technician

Local heating professionals are coming to your area

We’re onboarding Gas Safe registered and licensed HVAC engineers city by city. Check back soon, or search above to see current availability.

Written by TroubleAtlas Technical Team · Last updated: 2026-08-02 · Sources: manufacturer service documentation · How we verify
Scroll to Top