Weil-McLain error codes

The complete list of Weil-McLain fault codes shown on the display, each with what it means and the page that explains how it is diagnosed and fixed.

48documented codes
47with documented causes
Weil-McLain boiler with the fault code shown on the display
Quick Answer

Weil-McLain heating appliances display 48 documented error codes. Each code below opens its own page with the official meaning, the documented causes, the safety assessment and the parts involved.

01

All Weil-McLain Error Codes

48 codes, each with its own page. Click a code to open the meaning, the documented causes and the repair.

CodeWhat it means
AIR PRESSURE Switch OpenOccurs when Air Pressure connection is open
Auto Reset CountRecords number of lockouts that have automatically reset since this count was last cleared
BLOWER FAULTBlower unable to reach required speed or does not reach 0 RPM when turned off
Blower Fault 1Blower does not reach zero RPM within four minutes when mode is Standby or Prepump
Blower Fault 2Blower unable to reach required pre-purge speed or ignition speed Blower failed to complete calibration…
Blower Fault 3Blower is outside of minimum or maximum speed for 10 seconds
Blower Fault 4Blower drops to zero RPM while burner is firing
Boiler Output Sensor Flue SensorOccurs if dual temperature sensors values have spread by more that 10ºF
Clock FaultWhen the real time clock chip cannot be read
Closure Switch FaultClosure switch connections on P7 Pins 2 and 3 are open for more than 4 minutes
Closure Switch faultProof of Closure connections on J18, Pins 2 and 3 are open
Communication errorsOccurs if display or main control communications is out for 30 seconds
Configuration faultConfiguration data in the control safety micro does not match data in the control’s application micro
Control FaultRecords number
Control faultOccurs when micro- controllers on main board have a RAM or ROM error
DISPLAY COMM FaultOccurs if display communications out for 30 seconds
EXP BOARD COM FAULTExpansion Control Board communication fault
FALSE FLAMEOccurs if flame is detected when there should be no flame
FLAME FAULTOccurs if flame is detected when there should be no flame
FLAME LOSS FAULTFlame value dropped below the allowable Proof of Flame threshold while running
FLUE TEMP TOO HIGHOccurs if flue temperature sensor exceeds 210ºF (Warning) or 220ºF (Lockout)
Flame Circuit FaultWhen the digital flame input does not sense that the circuit discharged appropriately
Flue Temp Too HighOccurs if flue temperature sensor exceeds 210°F (Warning) or 220°F (Lockout)
GAS PRESSURE SW FAULTGas pressure switch is open (high or low)
GAS RELAY FAULT 1-4The control has detected a problem with the control board’s gas valve output circuit
GV FAULT EXPANSION BRDGas valve output of the Expansion module
HIGH TEMP LIMITBoiler temperature sensor reached High Temp Limit setting (no higher than 200° F)
HW FAULT EXPANSION BRDExpansion Control Board hardware has failed
Hardware FaultOccurs when micro-controllers on main board have a RAM or ROM error, or communication is cut off
Hardware Fault XThe control has detected a problem with its gas valve output circuit
IGNITION 1 FAULTBoiler went through two ignition attempts and either never detected flame, or flame sense value never reached…
IGNITION 2 FAULTBoiler went through two ignition attempts and did not meet running flame threshold for boiler model within 10…
IGNITION FAULTBoiler went through 5 ignition attempts and never detected flame or flame sense value never reached minimum…
Ignition RetriesDisplays the number of ignition attempts in the current ignition sequence
Internal Clock FaultOccurs when the internal clock of the control is out of sync
LIMIT OPENOccurs if manual or automatic reset limit opens
LOW FLAME SHUTDOWNFlame quality dropped below allowable Running Flame Threshold, but it did not go out
LOW WTR CONDITIONOccurs if the integrated LWCO sees no water
Lockout History 1Details of present or last recorded lockout
Lockout History 2Details of boiler during the second oldest lockout still in memory
Lockout History 3Details of boiler during the oldest lockout still in memory
MINIMUM AIR FLOW SWITCH FAULTMin air flow switch is open when it should be closed, or closed when it should be open
Manual Reset CountRecords number of lockouts that required a manual reset since this count was last cleared
OUTDOOR SENSOR ERROROutdoor temperature sensor short or OPEN
Outdoor Sensor ErrorOutdoor temperature sensor is short or open
PS Fault Exp. BoardPressure switch issue detected on expansion board
SUPPLY WATER TEMPERATURE TOO HIGHOccurs when the System Supply temperature goes above 200º F when the burner is running
Software IncompatibleMain control and display software are not compatible
02

What Fails Most Often on Weil-McLain

Grouped from the official meaning of each of the 48 codes above — not from opinion. The number is how many different fault codes point at that component.

ComponentCodesExamples
Ignition8FLAME FAULT, FLAME LOSS FAULT, Flame Circuit Fault, IGNITION 1 FAULT
Control Board6Control fault, EXP BOARD COM FAULT, GAS RELAY FAULT 1-4, HW FAULT EXPANSION BRD
Fan5BLOWER FAULT, Blower Fault 1, Blower Fault 2, Blower Fault 3
Temperature Sensor4Boiler Output Sensor Flue Sensor, HIGH TEMP LIMIT, OUTDOOR SENSOR ERROR, Outdoor Sensor Error
Pressure Switch3AIR PRESSURE Switch Open, GAS PRESSURE SW FAULT, MINIMUM AIR FLOW SWITCH FAULT
Communication3Communication errors, DISPLAY COMM Fault, Software Incompatible
Flue2FLUE TEMP TOO HIGH, Flue Temp Too High
Gas Valve2GV FAULT EXPANSION BRD, Hardware Fault X
03

Parts & Prices

The parts most often involved in the Weil-McLain faults listed above.

Ignition / spark electrode
OEM Part · Weil-McLain
Check price View price
PCB (printed circuit board)
OEM Part · Weil-McLain
Check price View price
Fan / blower assembly
OEM Part · Weil-McLain
Check price View price
Temperature sensor (NTC)
OEM Part · Weil-McLain
Check price View price
Compatible Ignition / spark electrode
Compatible · Generic
Check price View price
Compatible PCB (printed circuit board)
Compatible · Generic
Check price View price
Compatible Fan / blower assembly
Compatible · Generic
Check price View price
Compatible Temperature sensor (NTC)
Compatible · Generic
Check price View price
Reconditioned Ignition / spark electrode
Used / Tested · Weil-McLain
Check price View price
Reconditioned PCB (printed circuit board)
Used / Tested · Weil-McLain
Check price View price
Reconditioned Fan / blower assembly
Used / Tested · Weil-McLain
Check price View price
Reconditioned Temperature sensor (NTC)
Used / Tested · Weil-McLain
Check price View price

Prices and availability vary by region and are shown by the retailer, not by TroubleAtlas.

04

Diagnostic Tools

What an engineer uses to work through the codes on this page.

Digital Multimeter (TRUE RMS)

For testing electrode resistance and PCB voltages

$35–$80 View price

Gas Leak Detector

Essential for checking connections after any gas valve work

$25–$45 View price

Manometer / Pressure Gauge

To measure gas inlet and burner pressure

$40–$90 View price

Combustion Analyzer

For verifying flue gas readings after repair

$180–$350 View price
Full HVAC diagnostic toolkit
05

TroubleAtlas Pro

TroubleAtlas Pro — professional HVAC tools
For HVAC Professionals

Get cited by AI. Get found by customers.

TroubleAtlas Pro puts your business in front of homeowners searching for Weil-McLain faults, and structures your listing so AI assistants can cite you as a trusted source.

Explore TroubleAtlas Pro →

Considering a New Heating System

Considering a New Heating System?

If your Weil-McLain appliance is over 10 years old, replacing it with a modern condensing boiler or air-source heat pump could cut energy bills and remove the recurring faults listed on this page.

Compare Heating System Prices →
Professional heating system installation and service

YouTube Channel

TroubleAtlas · on YouTube

Watch the fixes. Follow the channel.

Step-by-step boiler repair guides, equipment reviews and heating system comparisons from qualified engineers.

New fixes every week
Weekly

Fix in 5

Quick fixes for common boiler faults explained in under 5 minutes

Head-to-Head

Boiler Comparator

Side-by-side comparisons of popular boiler models

Scored

Boiler Reviews

Independent reviews with TroubleAtlas Score ratings

Find a Specialist

Find help near you

Don’t fix it alone. Find a trusted heating engineer near you.

TroubleAtlas connects you with vetted local heating professionals who can inspect, diagnose and repair your Weil-McLain appliance safely — no guesswork, no unnecessary call-outs.

VettedNear youDirect contact
Are you a professional? Join our network →
Suggested engineer · your city Certified heating technician

Local heating professionals are coming to your area

We’re onboarding Gas Safe registered and licensed HVAC engineers city by city. Check back soon, or search above to see current availability.

Written by TroubleAtlas Technical Team · Last updated: 2026-08-02 · Sources: manufacturer service documentation · How we verify
Scroll to Top