Weil-Mclain GAS PRESSURE SW FAULT Error Code — Gas pressure switch is open (high or low) | Causes, Fix & Parts — TroubleAtlas

🌐 ▾
HVAC Error Code · Weil-Mclain
GAS PRESSURE SW FAULT

Gas pressure switch is open (high or low)

The GAS PRESSURE SW FAULT error code on Weil-Mclain boilers indicates gas pressure switch is open (high or low).

Severity: Medium
Weil-Mclain boiler shown with GAS PRESSURE SW FAULT fault code display
Quick Answer

Weil-Mclain GAS PRESSURE SW FAULT means: gas pressure switch is open (high or low). On this component the documented failure modes are wiring, connector or harness of the pressure switch damaged or loose, flue or air intake blocked or restricted or the pressure switch has failed — short circuit or open circuit. You can safely reset the boiler once — if GAS PRESSURE SW FAULT returns, do not keep resetting. A qualified heating engineer should diagnose the root cause.

01

What Does GAS PRESSURE SW FAULT Mean

The GAS PRESSURE SW FAULT code is shown by the boiler’s control board when it detects gas pressure switch is open (high or low). The boiler then stops instead of continuing to run in that condition: the code is the appliance reporting a problem, not proof that the boiler is broken.

What you see on the boiler
The display shows GAS PRESSURE SW FAULT and the boiler stops until the fault is cleared
02

Common Causes

The manufacturer does not publish a cause list for this specific code. The causes below are the failure modes documented for the same component on other boilers, confirmed by the service literature of 4 different manufacturers.

Cause
Wiring, connector or harness of the pressure switch damaged or loose
Flue or air intake blocked or restricted
The pressure switch has failed — short circuit or open circuit
Heat exchanger fouled or partially blocked
System water pressure too low, or a leak somewhere in the system
Too many reset attempts: the boiler has locked itself out
03

Safety Warning

!

GAS PRESSURE SW FAULT involves electrical or pressure-related components. Do not attempt repairs without proper qualifications. Ensure the boiler is electrically isolated before any inspection. If you notice water leaks, unusual sounds, or pressure anomalies, contact a qualified heating engineer immediately.

06

Parts & Prices

Ignition / spark electrode
OEM Part · Weil-Mclain
Check price View price
Gas valve assembly
OEM Part · Weil-Mclain
Check price View price
PCB (printed circuit board)
OEM Part · Weil-Mclain
Check price View price
Compatible Ignition / spark electrode
Compatible · Generic
Check price View price
Compatible Gas valve assembly
Compatible · Generic
Check price View price
Compatible PCB (printed circuit board)
Compatible · Generic
Check price View price
Reconditioned Ignition / spark electrode
Used / Tested · Weil-Mclain
Check price View price
Reconditioned Gas valve assembly
Used / Tested · Weil-Mclain
Check price View price
Reconditioned PCB (printed circuit board)
Used / Tested · Weil-Mclain
Check price View price

Prices shown are indicative. Actual prices and availability vary by region.

05

How to Fix It

1

Check gas pressure at tee mounted behind gas pressure switches during high and low fire and boiler off. Pressure should always be with limits on rating label. Undersized gas supply pipes or regulators may cause low gas pressure issues while the boiler is operating and possibly high gas pressure when the boiler shuts down

2

Insure the pressure regulator in the gas supply line is a lockup-type

3

Ensure gas pressure switch settings are correct. Low Pressure Switch Setting = 2 inches H2O High Pressure Switch Setting = 14 inches H2O

4

Unplug and re-seat the connector of the pressure switch, then check the harness for chafing, corroded pins and breaks in continuity.

5

Inspect the flue and air intake along their whole length, including the outside terminal, and clear any obstruction or debris.

6

Measure the resistance of the pressure switch with a multimeter and compare it against the manufacturer’s resistance-versus-temperature table; replace it if it is open circuit, short circuit or out of range.

Refer to the Weil-Mclain service documentation for the detailed procedure. Only a qualified engineer should carry out these repairs.

Comparison of new and old boiler parts
07

Diagnostic Tools

Digital Multimeter (TRUE RMS)

For testing electrode resistance and PCB voltages

$35–$80 View price

Gas Leak Detector

Essential for checking connections after any gas valve work

$25–$45 View price

Manometer / Pressure Gauge

To measure gas inlet and burner pressure

$40–$90 View price

Combustion Analyzer

For verifying flue gas readings after repair

$180–$350 View price
Full HVAC diagnostic toolkit
09

TroubleAtlas Score

TROUBLEATLAS · SCORE INDEPENDENT · VERIFIED ★★ TA 7.5/10

What Is the TroubleAtlas Score?

Every boiler model is independently evaluated and scored by TroubleAtlas across 6 dimensions: reliability, efficiency, parts availability, service network, value for money, and user satisfaction. The score helps you compare models and make informed decisions when choosing a new boiler.

See All Boiler Scores →
10

Boiler Breakdown Cover

Boiler Breakdown Cover

Protect against unexpected repair costs. Cover plans include annual service, emergency callouts within 24 hours, and full parts replacement. Compare plans side by side and choose the level of protection that fits your home and budget.

Coverage Plans — Coming Soon
11

Considering a New Heating System

Considering a New Heating System?

If your boiler or heat pump is over 10 years old, replacing it with a modern condensing boiler or air-source heat pump could save you up to 30% on energy bills and significantly reduce your carbon footprint.

Compare Heating System Prices →
Professional heating system installation and service
12

YouTube Channel

TroubleAtlas · on YouTube

Watch the fixes. Follow the channel.

Step-by-step boiler repair guides, equipment reviews, and heating system comparisons from qualified engineers.

New fixes every week
Weekly

Fix in 5

Quick fixes for common boiler faults explained in under 5 minutes

Head-to-Head

Boiler Comparator

Side-by-side comparisons of popular boiler models

Scored

Boiler Reviews

Independent reviews with TroubleAtlas Score ratings

13

Find a Specialist

Find help near you

Don’t fix it alone. Find a trusted heating engineer near you.

TroubleAtlas connects you with vetted local heating professionals who can inspect, diagnose and repair your boiler safely — no guesswork, no unnecessary call-outs.

Vetted Near you Direct contact
Are you a professional? Join our network →
Suggested engineer · your city Certified heating technician

Local heating professionals are coming to your area

We’re onboarding Gas Safe registered and licensed HVAC engineers city by city. Check back soon, or search above to see current availability.

14

TroubleAtlas Pro

TroubleAtlas Pro — professional HVAC diagnostic tools
For HVAC Professionals

Get cited by AI. Get found by customers.

TroubleAtlas Pro puts your business in front of homeowners searching for exactly this fault, and structures your listing so AI assistants can cite you as a trusted source.

  • ✓ Appear on error code pages viewed by thousands of homeowners
  • ✓ AI assistants cite your listing as a verified local specialist
  • ✓ Receive direct leads with customer name and contact details
  • ✓ TroubleAtlas Certified badge for your marketing materials
Explore TroubleAtlas Pro →
15

Affected Models

Weil-Mclain models that can display fault code GAS PRESSURE SW FAULT:

Model FamilyOutput RangeFrequency
All Weil-Mclain models—Possible
16

Frequently Asked Questions

What should be checked first when Weil-Mclain shows GAS PRESSURE SW FAULT?+

Check gas pressure at tee mounted behind gas pressure switches during high and low fire and boiler off. Pressure should always be with limits on rating label. Undersized gas supply pipes or regulators may cause low gas pressure issues while the boiler is operating and possibly high gas pressure when the boiler shuts down. According to the technical documentation, this is the first check on the list for GAS PRESSURE SW FAULT.

Can the boiler be reset after GAS PRESSURE SW FAULT?+

GAS PRESSURE SW FAULT is not classified as a high-severity fault, so the boiler can be reset once. If GAS PRESSURE SW FAULT comes back, stop resetting: the underlying cause is still there and needs a qualified heating engineer.

Written by TroubleAtlas Technical Team · Last updated: 2026-08-01 · Sources: 4