Electrolux tumble dryers fault codes
Every Electrolux tumble dryers fault code we have documented, with what it means. Pick yours to see causes, checks and the parts involved.
● 47 codes documented
Electrolux uses 47 fault codes on its tumble dryers, shown on the display when the machine stops — among them E31, E32, E42, E51, E52. Each one points to a specific part: on this page you find them all, with what they mean.
How to read the code on the display
On most Electrolux appliances the code appears on the display when the cycle stops, or is spelled out by a sequence of blinking lights.
Write the code down before switching off: many machines clear it when unplugged, and without the code the fault has to be found from scratch.
Replacement parts
Tools you'll need
Find a specialist
TroubleAtlas Pro
TroubleAtlas Certified

What is the TroubleAtlas Score?
Beyond fault codes and specialists, we rate the reliability of appliance brands and models — a transparent score that owes nothing to the manufacturer. The reference to check before you buy or repair.
See all appliance scores →TA YouTube Channel
All Electrolux codes
47 codes, in order. Click one to open its page.
| CODE | WHAT IT MEANS |
|---|---|
| E31 | Moisture sensor frequency too high |
| E32 | Moisture sensor frequency too low |
| E42 | Door sensing error |
| E51 | Motor relay failure |
| E52 | Motor stopped or not starting |
| E53 | Motor centrifugal switch failure |
| E54 | Motor sensing failure |
| E59 | No drive motor tachometer signal |
| E5A | Overheated inverter board |
| E5C | Voltage supply is too high (above 240 volts) |
| E5F | Inverter board failed to start the drive motor |
| E5H | TMotor voltage is too low (below 100 volts) |
| E61 | Heater relay failure |
| E63 | Heating element shorted to ground |
| E64 | Open heating element circuit |
| E65 | High limit thermostat tripped open too many times (Electric dryer) |
| E66 | Thermal limiter tripped |
| E67 | Heating sensor failure |
| E73 | Inlet thermistor failure |
| E74 | Drive motor relay failure |
| E91 | Communication, error |
| E92 | User interface control and electronic control board mismatch |
| E93 | Machine configuration error |
| E94 | Cycle configuration error |
| E95 | Power supply voltage error. The board detects abnormal line voltage |
| E97 | Program mismatch |
| EA1 | Incoming power frequency out of limits |
| EA2 | Incoming line voltage is above 130 volts AC |
| EA3 | Incoming line voltage is below 90 volts AC |
| EA4 | Improper wiring on the terminal block |
| EA5 | Electronic control board defective |
| EF1 | Blocked exhaust vent |
| EF3 | Maximum dry time has expired |
| EF8 | Stuck key on the user interface control |
| EX53 | Motor sensing circuit error |
| Ex51 | Drive motor failure |
| Ex52 | Drive motor thermal cut-out tripped |
| Ex54 | Jammed drive motor |
| Ex62 | Shorted compressor |
| Ex63 | Compressor not operating |
| Ex64 | Compressor sensor circuit failure |
| Ex71 | Temperature sensor failure |
| Ex91 | User interface communication failure |
| Ex9E | One or more user interface buttons don't work |
| ExH1 | Incoming power supply frequency out of limits |
| ExH2 | Power supply voltage too high (above 130 VAC) |
| ExH3 | Power supply voltage too low (below 100 VAC) |