SMA 9308: what the solar inverter code means

🌐 ▾
SOLAR FAULT CODE · SMA

9308 SMA — Battery system communication error

What fault code 9308 means on a SMA system, what usually causes it, and what to check first.

BRAND
SMA
CODE
9308 SBSExx-50
FAMILY
Inverters
SOURCE
manufacturer documentation · 2026-09-04
01

WHAT IT MEANS

Battery system communication error

02

COMMON CAUSES

What the manufacturer's own documentation gives as the cause. Where it lists more than one, they are in the order the documentation puts them — not in an order we invented.

  • Event 9308 indicates a communication error in the battery system
03

SAFETY WARNING

A solar system stays live even with the inverter switched off: the panels produce whenever there is light, and the DC side can exceed 600 volts. The checks described here are done with the system isolated; those that require opening the inverter belong to a qualified person.

04
WHAT IT TAKES

Buy the whole thing, or just the part

Two different needs, and we keep them apart on purpose: a complete system to buy and install yourself, or the single component that failed on a system you already have.

Buy the whole thing, or just the part
THE WHOLE THING

Complete systems and equipment

Bought as one piece, delivered ready to fit. This is where the off-grid reader buys: a kit, not a spare part.

THE SINGLE PART

Replacement components

For a system already on the roof: the component that failed, new or refurbished. Compare suppliers before buying.

05

HOW TO CHECK IT

The checks below are done with the system isolated. Anything that needs the inverter opened belongs to a qualified person.

06

HOW TO FIX IT

What the manufacturer says to do, in the order it says to do it.

  1. Ensure that the battery system is switched on correctly
  2. Check that the battery communication cable is connected correctly and that the CAN bus is wired correctly
  3. Make sure that: correct connection of the Enable and GND lines Cable category is at least Cat 5e, twisted pair maximum cable length: 10 m Sufficient stripping of 12 mm
  4. If multi-core stranded wires are used, use bootlace ferrules (12 mm)
  5. Check the grounding of the inverter and the battery system
07

TOOLS YOU'LL NEED

10

FREQUENT QUESTIONS

Can I reset this myself?

A reset clears the message, not the cause. If the fault comes back within minutes, the cause is still there and the reset only hides it.

Does the same number mean the same thing on another brand?

No. Every manufacturer uses its own numbering, and this is the single most common way to replace the wrong part.

Is the system dangerous while it shows this code?

The panels keep producing whenever there is light, whatever the inverter shows: the DC side can exceed 600 volts even with the unit switched off.

11

WHERE TO GO NEXT

The rest of the solar section: other fault codes for this brand, the family this unit belongs to, and the pages that compare what to buy.

Other codes on this brand

TroubleAtlas technical desk · Last checked: 2026-09-06 · Our method